GROWATT SPF 3500-5000 ES OFF-GRID INVERTER INSTALLATION INTRODUCTION

TECHNICAL PARAMETER

CHARACTERISTIC:

This is a multi-functional off grid photovoltaic Growatt Inverter, integrated with MPPT photovoltaic charging controller, high-frequency pure sine wave inverter and UPS functional module, which is very suitable for off grid backup power supply and self use system. The design of high-frequency transformer enables the machine to provide reliable power conversion in a small size. This inverter can also operate in battery free mode.

The WiFi/GPRS module is a plug and play monitoring device installed on the inverter. With this device, users can monitor the operation status of the photovoltaic system anytime, anywhere through mobile phones or websites.

FEATURE

*Rated power 3.5KW to 5KW, power factor 1
*MPPT range 120V~430V, 450Voc
* High frequency inverter is small in size and light in weight
*Pure sine wave AC output
*Solar and utility grids can power the load at the same time
*BMS communication with CAN/RS485
* Has the ability to work without batteries
*Up to 6 units can be run in parallel (only if batteries are connected)
*WIFI/GPRS remote monitoring (optional)

1. LCD displayLCD display2. Status indicator 3. Charging indicator 4. Fault indicator 5. Function keys 6. AC input

7. WiFi/GPRS communication interface 8. USB communication interface 9. CAN communication interface 10. RS485 communication interface 11. Dry node

12. PV input 13. Switch 14. Battery input 15. Parallel communication line interface 16. Parallel current sharing line interface 17. AC output 18. Circuit breaker

The Growatt Inverter SPF 3500-5000 ES is a 230VAC output voltage shutdown gnid inverter for backup power and self-consumption applications with a maximum PV input voltage up to 450VDC. It can also
work without batteries, saving system investment costs.

This is a multifunctional 230V off-grid solar inverter that integrates MPPT solar charge controller, high-frequency pure sine wave inverter and UPS functional modules, which is very suitable for off-grid backup power and self-use applications. This hybrid inverter can be used with or without a 48V battery.

Can be connected to various household appliances and office loads, power tools, industrial equipment, electronic audio and video equipment, including refrigerators, lamps, TV sets, fans, air conditioners and other AC loads

IMPORTANT NOTE:

1.  This is a  wide-voltage hybrid inverter,  the voltage at which the solar panel is connected  must be above 150V for the hybrid inverter to work properly. Means you can connect solar panels in series, saving the cost of buying wires

The entire system also requires other equipment for complete operation, such as photovoltaic modules, generators or the utility grid.

  1. Rated power 5KW, power factor 1 MPPT range 120V~430V,  450Voc
  2. Small size and light weight high frequency inverter pure sine wave AC output
  3. Battery charging mode and load working mode can be set
  4. Inverter charging output time is adjustable
  5. Solar and utility grid can supply power to loads at the same time BMS communication using CAN/RS485
  6. Works without batteries
  7. Up to 6 units can be operated in parallel (only with batteries connected)
  8. The WiFi/GPRS module is a plug-and-play monitoring device installed on the inverter. Using this device, users can monitor the status of photovoltaic systems anytime, anywhere through their mobile phones or websites. (optional, additional purchase required)

2

WARN! MAKE SURE ALL INVERTERS WILL SHARE THE SAME BATTERY PACK. OTHERWISE, THE INVERTER WILL GO INTO FAULT MODE.

Up to 6 units can be operated in parallel (only with batteries connected)

The inverter can be used in parallel with two different operating modes.

1. Up to 6 single-phase units can be operated in parallel.

2. Up to 6 units work together, supporting three-phase devices. Four units support up to one phase.

warn!

All inverters must be connected to the same battery and ensure that each set of cables from the inverter to the battery is the same length.

Important note:

The ground and neutral conductors of the SPF 5000 ES are not connected together and the enclosure does not become part of the ground loop.

Test method: Use the buzzer of the multimeter to measure whether the zero wire and the ground wire are connected together. If they are connected together, a “beep” will sound. If there is no sound, there is no connection.

BATTERY CHARGING MODE AND LOAD WORKING MODE CAN BE SET

ES

太阳能逆变器

Wiring Instructions (When Your System Is A Split-Phase System (120V L+ 120V L+ N+G), Please Use This As A Reference)

  1. Connect  the ground wire  to the  ground  terminal (be sure to connect the PE protective conductor first).
  2. Connect AC input  L1 to the input  L (hot)  terminal.
  3. Connect AC input  L2 to the Input  Neutral  terminal.
  4. Connect  output L (hot)  to AC output  L1 .
  5.  Connect  output neutral  to AC output  L2 .
  6. Do not connect AC input neutral or load neutral to the inverter.

Important note:

  • This single-phase 220V solar inverter is an international version and can be used in 220Vac single-phase systems and 120V/240V split-phase systems.
  • This inverter charge can be connected to a separate 240V to 120/240 volt split phase transformer (not included) for two separate 120V hot wires for 120V loads.
  • This inverter only outputs 220Vac. It doesn’t output 120Vac.

 

500

MPPT Solar Charging Mode

  • maximum. Photovoltaic array power: 6000W
  • maximum. PV input current: 18A (PV to inverter)
  • Start voltage: 150Vdc±10Vdc
  • maximum. PV array open circuit voltage:  450Vdc
  • maximum. PV charging current: 100A  (inverter to battery)
  • maximum. Charging current (AC charger plus solar charger): 100A

warn:

  • Do not install the inverter on flammable building materials.
  • For installation on concrete or other non-combustible surfaces only.
  • Ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • A separate DC overcurrent protector or disconnect is required between the battery and the inverter.
  • All wiring must be performed by qualified personnel.
  • Connecting the battery with the proper cable is important for the safe and efficient operation of the system. To reduce the risk of injury, use 2AWG cable. Maximum torque 2Nm

Company Profile

Growatt was founded in 2010 and is a worldwide leader of smart energy solutions.

Growatt Inverter is a new energy enterprise dedicated to the R&D and manufacturing of PV inverters including on-grid, off-grid and storage inverters, and user side smart energy management solutions as well. The power capacity of Growatt on-grid inverters ranges from 1kW to 100 kW, meanwhile its off-grid and storage inverters cover a power range from 1 kW to 630 kW. Growatt inverters are extensively used worldwide for applications in residential, commercial, utility-scale scenarios as well as other storage power station projects.

Exhibition

Since its foundation in 2010, Growatt Inverter  has established branch offices one after another in Germany, US, UK, Australia,
Thailand,India, Netherlands, etc in order to better serve the customers across the globe. Growatt always sticks to the R&D
investment and technology innovation, and provides customers with premium products and services through its core invertertec hnology, rigorous quality control and continuous improvement of customer service. By end of September 2018, Growatt has shipped over 1.2 million inverters to over 100 countries and regions across the globe, growing into a Global Top 10 Inverter Brand and becoming the No.1 Chinese Residential PV Inverter Brand.

The application case

Product Packagin


HELPFUL BLOG:

No Utility Grid Connection

Cause Analysis:If the AC side is disconnected, the inverter will not be able to detect the voltage of the mains.

Method of exclusion:Remove the output port of the inverter, and use the AC voltage range of a multimeter to measure whether the voltage (phase voltage) between the live wire and the neutral wire on the user side of the output port is 220V. If there is no AC 220V, it is judged that there is no problem on the inverter side If the external AC side is open circuit, it is necessary to check whether the safety switches such as air switch, knife switch, overvoltage and undervoltage protector are damaged or open circuit.

PV System Power Generation Is Low

Cause Analysis:The power generation problem is related to many factors, weather, temperature, shading, inverter, component orientation, component inclination, etc.

Check method:Weather: haze, rainy days, cloudy days, and bad weather will make the power generation of the system low.

In terms of temperature: photovoltaic panels have the best working temperature, so too high or too low temperature will lead to low conversion efficiency of the panels, resulting in low power generation of the photovoltaic system.

Occlusion: Check the surrounding environment for obstructions, including nearby trees, utility poles, storage tanks of solar water heaters, drying clothes, bird droppings on battery panels, front row of photovoltaic panels covering the back row, etc. The MPPT tracking of the inverter is like the barrel effect, so it is greatly affected by occlusion. If a block is occluded, the conversion efficiency of the entire string will be reduced, thereby affecting the power generation of the system.

Component orientation: Components with different orientations cannot be connected to the same MPPT, which will affect the tracking of the core inverter in the photovoltaic system, thereby affecting the power generation of the system.

Module inclination: Note that the installation inclination of the module should be the best angle for the local irradiation; different inclinations have different conversion efficiencies of photovoltaic panels at the same time, so when the solar irradiance is the strongest (generally 11 noon at noon) : 00 to 2:00 pm), the inclination angle of the appropriate module receives the most solar energy; different inclination angle power generation systems will produce different peaks, and by comparison, it can be found that the optimal inclination angle of the system is not the optimal inclination angle. Power generation is low.

Photovoltaic panel reasons: PV panels of different brands cannot be connected to the same string and MPPT. Note that damaged photovoltaic panels will affect the power generation of the entire string. If you encounter damaged strings, please replace them in time.

Inverter reason: The inverter does not generate electricity when it reports a fault, which will affect the power generation. The DC open circuit voltage should be set in the appropriate range of the inverter, and the board is not properly matched. For example, the open circuit voltage of the board is not the MPPT voltage of the inverter. Within the range, it will affect the power generation efficiency of the inverter, thereby affecting the power generation of the photovoltaic system.

Power grid reasons: power grid fluctuations occur from time to time, ensuring the quality of the power grid is an important condition to ensure the normal power generation of the inverter, so pay attention to grid voltage fluctuations, frequency fluctuations, etc., which will affect the power generation of the inverter, and even cause the inverter to report a fault. Nearby high-power capacitive inductive loads will also affect the quality of the power grid, thereby affecting the power generation of the inverter.

The Grid Voltage Is Too High

Cause analysis: The mains voltage exceeds the voltage range of the inverter’s normal grid-connected operation. If the grid voltage is too high, it will exceed the inverter’s factory-set grid-connected voltage upper limit (the factory-set voltage range is 195Vac~253Vac); it generally occurs in household distribution. If the photovoltaic power generation users cannot digest the surplus electricity locally, the line impedance is too large during the online process, causing the voltage on the output side of the inverter to be too high, causing the inverter protection to be disconnected from the grid or run at reduced load. It is also possible that the voltage fluctuation range of the rural grid itself is relatively large, and it is easy to exceed the upper limit of the inverter voltage, resulting in load reduction or off-grid.

Method of exclusion:Increase the output cable, the thicker the cable, the lower the impedance; the inverter is installed as close as possible to the grid connection point, the shorter the cable, the lower the impedance; change the resistivity of the cable, the resistivity of copper wire is much smaller than that of aluminum wire, generally Use copper wire; if the voltage of the rural grid itself exceeds the grid-connected voltage range of the inverter, the upper limit of the grid-connected voltage of the inverter can be adjusted appropriately.

Insulation Resistance Is Too Low

Cause Analysis:The inverter has the function of detecting the insulation resistance of the DC side. When the insulation resistance of the DC side is detected to be lower than 50kΩ, the inverter will report “PV insulation resistance is too low fault”. The DC components are leaking, and the DC side of the inverter is short-circuited to ground.

Troubleshooting:Disconnect the AC circuit breaker and the DC circuit breaker; use the special MC4 dismantling wrench to remove the positive and negative poles of the DC measurement string; ensure that the component bracket is reliably grounded; Read the measured positive-to-ground impedance reading of each channel, then connect the red test lead to the negative pole of the string, and then read the negative-to-ground impedance reading of each channel. If it is greater than 50kΩ, the inverter judges that the insulation of the string is reliable, less than or equal to 50kΩ, the inverter judges that there is a problem with the insulation of the string, the inverter will automatically protect and stop working and report “PV insulation resistance is too low”.

PV Voltage Too High

Cause Analysis:Different inverters have different DC voltage input ranges, so the number of solar panels in the string should be configured according to the DC voltage input range of the inverter, and the report “PV voltage high voltage” is generally due to the solar panels of the string. The number is too large, which is caused by exceeding the DC voltage range of the inverter.

Troubleshooting:Check the parameters of the inverter, the input range of the DC voltage, and then measure the open-circuit voltage of the string (the open-circuit voltage refers to the voltage of the string when the inverter is not connected to the grid).

PV Voltage Too Low

PV voltage refers to the open circuit voltage of the string, that is, the positive and negative voltages measured after the solar panels are connected in series. On the contrary, the terminal is loose and the contact is poor, and the string is disconnected.

Troubleshooting:To measure the PV voltage of the string, the DC voltage level of the multimeter is required. The red test lead is connected to the positive electrode, and the black test lead is connected to the negative electrode. Read the displayed reading of the multimeter. If the reading is within the rated input range of the inverter and is a positive number, the PV voltage is normal. .

Mobile APP Monitoring Lost Contact

Cause Analysis:There is no communication between the collector and the inverter; the collector is not powered on: the APP scans the serial number of the inverter; the installation position signal problem; the internal reason of the collector;

Troubleshooting:Check whether the 232 interface DIP switch is turned on; check whether the 232 interface is in contact with the collector; check whether the data communication of the inverter 232 interface is normal;

Scan the serial number of the collector, or manually enter the serial number and check code of the collector; check whether the installation location is blocked by the signal, or the WiFi collector cannot receive the router signal, and the GPRS is installed in the local without the network signal of the internal traffic card operator (Telecom traffic card cannot be used); observe the flashing light of the collector. If the external conditions are no problem, the collector does not have any connection response, which can be considered as an internal fault of the collector.

DC Draw Arc

Cause Analysis:Arc pulling occurs because the strings form a loop and there is current output, so arcing occurs. The possible reason is that the inverter is working and the strings are directly inserted and removed, or the positive and negative poles between the strings are short-circuited, and the positive and negative poles are reversed. The number of strings connected in series is unbalanced, etc.

Troubleshooting:Before plugging and unplugging strings, check that the inverter has been normally closed before plugging and unplugging. The inverter has current input in the working state, and the operation of plugging and unplugging strings will cause arcing phenomenon; check whether there is a positive or negative short circuit in the strings. Check whether the positive and negative of the strings are reversed, and then connect them to the inverter. When the strings with opposite polarities are connected to the same mppt, it is equivalent to connecting two strings to form a short-circuit arc; The number of solar panels connected in series is inconsistent, and in the same mppt, there will be perfusion between the strings, and arcs will be formed when the strings are inserted and removed.

11 reviews for GROWATT SPF 5000 ES OFF GRID, 5KW, 48V, BIG PV INPUT

    GROWATT SPF 5000 ES OFF GRID, 5KW, 48V, BIG PV INPUT photo review
    Imane
    November 10, 2022
    The quality is very good, fully in line with the seller's description. I really like it. This is completely beyond expectations. Delivery is very fast. The packing is very careful and tight. The logistics company has a good service attitude and the delivery speed is very fast.
    GROWATT SPF 5000 ES OFF GRID, 5KW, 48V, BIG PV INPUT photo review
    Carlisle
    November 2, 2022
    This 5000ES inverter is really great. I learned about this product on this website, and then placed an order on the website. If there is a problem, we can also contact WhatsApp on the website. Jerry's service is very good, and he will reply to your message in a timely manner. This brand is also very good. I am going to expand my power generation. Recently, I am going to order more inverters. I will also buy them here, because I feel relieved here
    Belmore
    October 26, 2022
    Very good product, satisfactory brand, simple installation, easy to use, ready to place an order again in a few days
    Festus song
    October 24, 2022
    The growatt is very good. The installation is very tall. The price is cheap. Trust the growatt inverter and look forward to the experience after use
    GROWATT SPF 5000 ES OFF GRID, 5KW, 48V, BIG PV INPUT photo review
    Bright
    October 21, 2022
    The product quality is very good, the goods are good! I often shop online, and I'm very satisfied with everything every time. It's really convenient. This company is very convenient for sea and air transportation, and the after-sales service is also global. I don't need to worry about after-sales problems at all. I've used it for a long time, and there are no quality problems. You can buy it with confidence. I highly recommend it. Later, I will also buy more, and have a pleasant shopping
    GROWATT SPF 5000 ES OFF GRID, 5KW, 48V, BIG PV INPUT photo review
    dagen
    October 20, 2022
    Professional brand, professional customer service, professional equipment and packaging are very good. The products inside are well protected. I really like it and support it very much, which is completely beyond expectations. Delivery is very fast. The packing is very careful and tight. The logistics company has a good service attitude and the delivery speed is very fast. Satisfactory shopping quality is very good. I hope more friends can trust it.
    GROWATT SPF 5000 ES OFF GRID, 5KW, 48V, BIG PV INPUT photo review
    Cary Caspar
    October 19, 2022
    Easy to install, took a long time, very good quality, will continue to buy
    GROWATT SPF 5000 ES OFF GRID, 5KW, 48V, BIG PV INPUT photo review
    Mohsin Mahgoub
    October 17, 2022
    Perfect Deal.The item is good and delivery is fast. I am running the inverter in connection with 15 each 195W panels connected in serial/parallel to get 60V for my 48V battery system, on a self designed solar racking system, tracking the sun from E to W with a real good daily production of up to 16kwh so not to bad, of course this is under the Florida sun. I do use the SmartESS to record all my data. I am giving it 5 stars, even thou sometimes I do fight the change of settings between 4-5 and 14 but one of this days I hope to figure it out - or if you the reader know something that can help me me.
    Justin
    October 14, 2022
    Easy to operate, good performance, will buy again, home or commercial is a very good choice, the brand is also very reliable
    David
    October 10, 2022
    If I could have given the service a higher rating I would have done, Truly a great service and communication from the supplier. Fantastic product and well packaged for protection.
    Malaysia
    October 9, 2022
    Perfect Deal.The item is good and delivery is fast, easy to chat and will answers your concerns easily, I recommend he to anybody who wish to do business with he.
Add a review
Review now to get coupon!

Your email address will not be published. Required fields are marked *